Contec Cms50m Diagnosis Equipment Wireless Finger Pulse Oximetry

Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Pulse Oximeter

Product Description

Basic Information

ModelCMS50M
GroupMiddle-aged and Old
FunctionSpO2 & Pulse Rate
FeaturesAuto Power on/Standby
IndicationLow-Voltage Warning
PR Range30bpm~250bpm
SpO2 Range0%~100%
Dimensions57mm x 34mm x 31mm

Color Finger Pulse Oximeter

Model: CMS50M

Pulse Oximeter Display
Pulse Oximeter Usage

Introduction: The CMS50M Pulse Oximeter adopts Photoelectric Oxyhemoglobin Inspection Technology in accordance with Capacity Pulse Scanning & Recording Technology, which can be used to measure human oxygen saturation and pulse rate through finger. The device is suitable for being used in family, hospital, oxygen bar, community healthcare and physical care in sports, etc. (It can be used before or after exercise, but not recommended to use during exercising).

Key Features:

  • Accurate measurement of SpO2 and Pulse Rate
  • Clear display of SpO2, Pulse Rate, and bar graph
  • Low battery voltage indication
  • Automatic shut off when no signal is detected
  • Energy-saving auto standby mode

Technical Performance

Parameter Specifications
SpO2 Measuring Range 0% ~ 100% (Resolution: 1%)
Accuracy (SpO2) 70%~100%: ±2%; 0%~69%: unspecified
PR Measuring Range 30bpm ~ 250bpm (Resolution: 1bpm)
Accuracy (PR) ±2 bpm or ±2%, whichever is greater
Low Perfusion Performance SpO2 accuracy: ± 4% at 0.4% perfusion
Working Current ≤30mA
Power Supply Two "AAA" batteries
Safety Class Internally powered equipment, type BF applied part

Product Gallery

Oximeter detail 1
Oximeter detail 2
Oximeter detail 3
Oximeter detail 4
Oximeter detail 5

Frequently Asked Questions

1. What primary health metrics does the CMS50M measure?
The CMS50M measures Oxygen Saturation (SpO2) and Pulse Rate (PR) accurately through a non-invasive finger-tip sensor.
2. Can I use this device while exercising?
It is recommended to use the device before or after exercise. It is not recommended for use during active physical movement as it may affect the accuracy of the readings.
3. Does the oximeter have an automatic power-saving feature?
Yes, the device includes an auto standby function and will shut off automatically when no signal is detected to preserve battery life.
4. What type of batteries does the device require?
The CMS50M is powered by two standard "AAA" batteries.
5. What is the accuracy range for SpO2 levels?
The accuracy is ±2% for SpO2 levels between 70% and 100%. For levels below 69%, the accuracy is unspecified.
6. How portable is the CMS50M?
It is highly portable with compact physical dimensions of 57mm(L) x 34mm(W) x 31mm(H), making it easy to carry for home or travel use.